Augmented Mitral Valve Leaflet Area Decreases Leaflet Stress: a Finite Element Simulation

BACKGROUND: Using human MV models derived from three-dimensional (3D) echocardiography, finite element analysis (FEA) was used to predict mechanical leaflet and chordal stress. Subsequently, valve geometries were altered to examine the effects on stresses of: (1) varying coaptation area, (2) varying...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Xu, Chun, Jassar, Arminder S., Nathan, Derek P., Eperjesi, Thomas J., Brinster, Clayton J., Levack, Melissa M., Vergnat, Mathieu, Gorman, Robert C., Gorman, Joseph H., Jackson, Benjamin M.
Formato: Artigo
Idioma:Inglês
Publicado em: 2012
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC3462015/
https://ncbi.nlm.nih.gov/pubmed/22397985
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.athoracsur.2012.01.069