Prediction of Therapy Tumor-Absorbed Dose Estimates in I-131 Radioimmunotherapy Using Tracer Data Via a Mixed-Model Fit to Time Activity

BACKGROUND: For individualized treatment planning in radioimmunotherapy (RIT), correlations must be established between tracer-predicted and therapy-delivered absorbed doses. The focus of this work was to investigate this correlation for tumors. METHODS: The study analyzed 57 tumors in 19 follicular...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Schipper, Matthew J., Koral, Kenneth F., Avram, Anca M., Kaminski, Mark S., Dewaraja, Yuni K.