Convenient quantification of methanol concentration detection utilizing an integrated microfluidic chip

A rapid and simple technique is proposed for methanol concentration detection using a PMMA (Polymethyl-Methacrylate) microfluidic chip patterned using a commercially available CO(2) laser scriber. In the proposed device, methanol and methanol oxidase (MOX) are injected into a three-dimensional circu...