Refractive accuracy after intraocular lens implantation in pediatric cataract

AIM: To analyze the factors that influence the prediction error (PE) after intraocular lens (IOL) implantation in pediatric cataract. METHODS: The medical records of cataract patients of no more than 14 years old who had primary IOL implantation were reviewed from 2006 to 2010. The PE, absolute valu...