Acute thrombosis of mechanical bi-leaflet aortic valve prosthesis

Thrombosis of mechanical aortic valve prosthesis is a rare but life-threatening complication. In most reported cases, inadequate anticoagulation or cessation of anticoagulation is the cause of prosthesis thrombosis. The case of a 70-year-old male patient hospitalized for severe dyspnoea is presented...