Codi QR

Aneurysm following ligation of patent ductus arteriosus.

Complications following ligation of patent ductus arteriosus are rare. Aneurysm following ligation requires careful evaluation and individualized repair. We report 2 cases that highlight the clinical course and operative management of this unusual but significant postoperative complication. IMAGES:

Guardat en:
Dades bibliogràfiques
Publicat a:Tex Heart Inst J
Autors principals: De, D H, Pezzella, A T
Format: Artigo
Idioma:Inglês
Publicat: Texas Heart Institute 1995
Matèries:
Accés en línia:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC325282/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/8605434/
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!