The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty: A study of validity and reliability

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is a highly accurate tool for assessment of polyethylene (PE) wear in total hip arthroplasty (THA); however, PE wear measurements in clinical studies are often limited to plain radiographs. We evaluated the agreement between PE wear measured w...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Main Authors: Stilling, Maiken, Larsen, Kristian, Andersen, Niels T, Søballe, Kjeld, Kold, Søren, Rahbek, Ole
Format: Artigo
Sprog:Inglês
Udgivet: Informa Healthcare 2010