Change of working length in curved molar root canals after preparation with different rotary nickel-titanium instruments

AIM: The purpose of this study was to investigate change of working length in curved molar root canals after preparation with Profile, ProTaper and K3 Rotary Nickel-Titanium (Ni-Ti) instruments. MATERIALS AND METHODS: One hundred and eighty maxillary and mandibular molars were divided into group I h...