Carregant...

Technical Solutions to Ensure Safe Yttrium-90 Radioembolization in Patients With Initial Extrahepatic Deposition of (99m)Technetium–Albumin Macroaggregates

PURPOSE: To evaluate the incidence of extrahepatic deposition of technetium-99m–labeled albumin macroaggregates ((99m)Tc-MAA) after pretreatment angiography, before yttrium-90 radioembolizaton ((90)Y-RE), and to report on technical solutions that can be used to ensure safe delivery of (90)Y-microsph...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Barentsz, M. W., Vente, M. A. D., Lam, M. G. E. H., Smits, M. L. J., Nijsen, J. F. W., Seinstra, B. A., Rosenbaum, C. E. N. M., Verkooijen, H. M., Zonnenberg, B. A., Van den Bosch, M. A. A. J.
Format: Artigo
Idioma:Inglês
Publicat: Springer-Verlag 2010
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC3170462/
https://ncbi.nlm.nih.gov/pubmed/21191588
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1007/s00270-010-0088-4
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!