Recurring Extracorporeal Circuit Clotting During Continuous Renal Replacement Therapy Resolved after Single-Session Therapeutic Plasma Exchange

We report a case of a 17 year old white male with multiple fractures and multi-organ failure who developed oliguric acute renal failure requiring continuous renal replacement therapy. Repeated clotting of the extracorporeal circuit (ECC) prevented delivery of a minimally acceptable dose of renal rep...