Perfusion systems that minimize vascular volume fraction in engineered tissues
This study determines the optimal vascular designs for perfusing engineered tissues. Here, “optimal” describes a geometry that minimizes vascular volume fraction (the fractional volume of a tissue that is occupied by vessels) while maintaining oxygen concentration above a set threshold throughout th...