Automated computation of functional vascular density using laser speckle imaging in a rodent window chamber model

We report a methodology for computing functional vascular density within a rodent dorsal window chamber model based on long-exposure laser speckle imaging (LSI). This technique relies on the presence of flow to create detailed vasculature maps. Employing this contrast mechanism is not possible using...

詳細記述

保存先:
書誌詳細
主要な著者: White, Sean M., George, Steven C., Choi, Bernard
フォーマット: Artigo
言語:Inglês
出版事項: 2011
主題:
オンライン・アクセス:https://ncbi.nlm.nih.gov/pmc/articles/PMC3137926/
https://ncbi.nlm.nih.gov/pubmed/21419785
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.mvr.2011.03.006