A carregar...
A Validated Stability-Indicating Liquid-Chromatographic Method for Ranitidine Hydrochloride in Liquid Oral Dosage Form
A selective, specific and stability-indicating gradient reverse phase high-performance liquid chromatographic (HPLC) method was developed for the determination of Ranitidine in presence of its impurities, forced degradation products and placebo substances such as saccharide and parabens. Ultraviolet...