Lataa...

Systematic characterization of degas-driven flow for poly(dimethylsiloxane) microfluidic devices

Degas-driven flow is a novel phenomenon used to propel fluids in poly(dimethylsiloxane) (PDMS)-based microfluidic devices without requiring any external power. This method takes advantage of the inherently high porosity and air solubility of PDMS by removing air molecules from the bulk PDMS before i...

Täydet tiedot

Tallennettuna:
Bibliografiset tiedot
Päätekijät: Liang, David Y., Tentori, Augusto M., Dimov, Ivan K., Lee, Luke P.
Aineistotyyppi: Artigo
Kieli:Inglês
Julkaistu: American Institute of Physics 2011
Aiheet:
Linkit:https://ncbi.nlm.nih.gov/pmc/articles/PMC3124517/
https://ncbi.nlm.nih.gov/pubmed/21716807
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1063/1.3584003
Tagit: Lisää tagi
Ei tageja, Lisää ensimmäinen tagi!