Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus Surgery

PURPOSE: To evaluate and compare the efficacy and tolerance of fibrin glue and sutures for closing conjunctival wounds in strabismus surgery. METHODS: In a prospective trial, we performed strabismus surgery using limbal incisions. Conjunctival wounds were closed with fibrin glue in 20 eyes of 20 pat...