Direct measurement of free radical generation following reperfusion of ischemic myocardium.

Electron paramagnetic resonance spectroscopy was used to directly measure free radical generation in perfused rabbit hearts. Hearts were freeze-clamped at 77 degrees K during control perfusion, after 10 min of normothermic global ischemia (no coronary flow), or following post-ischemic reperfusion wi...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Udgivet i:Proc Natl Acad Sci U S A
Principais autores: Zweier, J L, Flaherty, J T, Weisfeldt, M L
Format: Artigo
Sprog:Inglês
Udgivet: National Academy of Sciences 1987