RP-HPLC Method for Simultaneous Estimation of Frusemide and Amiloride Hydrochloride in Tablet Formulation
A new reverse phase high performance liquid chromatography method for the simultaneous estimation of frusemide and amiloride hydrochloride in tablet formulation is developed. The determination was carried out on a HIQ SIL, C18 (250×4.6 mm, 5 µm) column using a mobile phase of 50 mM phosphate buffer...