LIMITATIONS OF MOTOR SEIZURE MONITORING IN ECT
Seizures were monitored using both cuff method and EEG, during the first ECT session in 158 consecutive patients. All developed adequate EEG seizures (≥25 seconds). Twelve patients (8%) did not develop adequate motor seizures (15 seconds), of whom ten had no convulsive response. EEG seizure duration...