Wird geladen...
Dose perturbations from implanted helical gold markers in proton therapy of prostate cancer
Implanted gold fiducial markers are widely used in radiation therapy to improve targeting accuracy. Recent investigations have revealed that metallic fiducial markers can cause severe perturbations in dose distributions for proton therapy, suggesting smaller markers should be considered. The objecti...