Effective glomerular filtration pressure and single nephron filtration rate during hydropenia, elevated ureteral pressure, and acute volume expansion with isotonic saline

Free-flow and stop-flow intratubular pressures were measured in rats with an improved Gertz technique using Landis micropipets or a Kulite microtransducer. In hydropenia, average single nephron glomerular filtration rate was 29.3 nl/min, glomerular hydrostatic pressure (stop-flow pressure + plasma c...