The Effect of Methodological Differences in the Measurement of Stapes Motion in Live and Cadaver Ears

Methodological differences in sound-induced stapes velocity (Vs) measurements in live and cadaveric ears were examined using fresh cadaveric temporal bones. On average, differences in preparation (sectioning the stapedius tendon, removing the facial nerve, and widely opening the facial recess) had s...