BRAIN BLOOD FLOW AND VELOCITY: CORRELATIONS BETWEEN MAGNETIC RESONANCE IMAGING AND TRANSCRANIAL DOPPLER
OBJECTIVE: Because transcranial Doppler TCD is unable to measure arterial diameter, it remains unproven whether the changes in cerebral blood velocity it measures are representative of changes in cerebral blood flow. Our study was designed to compare velocity changes to flow changes measured by two...