Combined replacement of the ascending aorta and the aortic valve in 42 consecutive patients: A comparison of composite graft techniques and conventional techniques over one year

During 1978, 42 consecutive patients underwent simultaneous aortic valve and ascending aorta replacement in our institution. Seventy-one percent were at low risk despite a high incidence of dissection. Twenty-nine percent were high-risk patients requiring repeat or concomitant cardiac procedures, mo...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Beddermann, Christoph, Norman, John C., Cooley, Denton A.
Formato: Artigo
Idioma:Inglês