PERFUSION FOR MYOCARDIAL REVASCULARIZATION WITHOUT AN ARTIFICIAL OXYGENATOR (New Method to Reduce Surgical Morbidity)

Thirteen patients were submitted to direct myocardial revascularization (saphenous vein graft) without the use of an artificial oxygenator. The perfusion was done by a left ventricle-to-aorta bypass and autogenous oxygenation. Most patients had three grafts implanted plus endarterectomy of the dista...