Chargement en cours...

PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography

INTRODUCTION: Lung protective ventilation requires low tidal volume and suitable positive end-expiratory pressure (PEEP). To date, few methods have been accepted for clinical use to set the appropriate PEEP. The aim of this study was to test the feasibility of PEEP titration guided by ventilation ho...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Zhao, Zhanqi, Steinmann, Daniel, Frerichs, Inéz, Guttmann, Josef, Möller, Knut
Format: Artigo
Langue:Inglês
Publié: BioMed Central 2010
Sujets:
Accès en ligne:https://ncbi.nlm.nih.gov/pmc/articles/PMC2875520/
https://ncbi.nlm.nih.gov/pubmed/20113520
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1186/cc8860
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!