Φορτώνει......
NERVE MEMBRANE CURRENT NOISE: DIRECT MEASUREMENTS UNDER VOLTAGE CLAMP
Fluctuations in the steady-state current of the membrane of the lobster giant axon have been measured under voltage-clamp conditions. These fluctuations have a power density spectrum that is inversely proportional to frequency. The magnitude of the fluctuations is determined largely by the potassium...
Αποθηκεύτηκε σε:
| Τόπος έκδοσης: | Proc Natl Acad Sci U S A |
|---|---|
| Κύριος συγγραφέας: | |
| Μορφή: | Artigo |
| Γλώσσα: | Inglês |
| Έκδοση: |
National Academy of Sciences
1969
|
| Θέματα: | |
| Διαθέσιμο Online: | https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC286131/ https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/5263026/ https://ncbi.nlm.nih.govhttps://doi.org/10.1073/pnas.64.1.95 |