A New Approach to Electromagnetic Blood Flow Determination by Means of Catheter in an External Magnetic Field
Maximal reduction in transverse catheter dimension has been achieved for the purpose of creating an intravascular electromagnetic flow sensor capable of percutaneous introduction into the vascular system. The electrodes are mounted on a flexible frame which collapses as it passes through a small bra...