Carregant...
Removal of a broken intramedullary femoral nail with an unusual pattern of breakage: a case report
To the best of our knowledge, only 3 cases, including the present case, have been reported with a three part broken pattern. However, this is the first case associated with a distal locking screw broken. We report the case of a 31-year-old patient who sustained an open femoral shaft fracture . The f...
Guardat en:
| Autors principals: | , , |
|---|---|
| Format: | Artigo |
| Idioma: | Inglês |
| Publicat: |
Springer Milan
2009
|
| Matèries: | |
| Accés en línia: | https://ncbi.nlm.nih.gov/pmc/articles/PMC2787202/ https://ncbi.nlm.nih.gov/pubmed/19777163 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1007/s11751-009-0066-z |
| Etiquetes: |
Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
|