Removal of a broken intramedullary femoral nail with an unusual pattern of breakage: a case report
To the best of our knowledge, only 3 cases, including the present case, have been reported with a three part broken pattern. However, this is the first case associated with a distal locking screw broken. We report the case of a 31-year-old patient who sustained an open femoral shaft fracture . The f...