Dynamic MRI of Grid-Tagged Hyperpolarized Helium-3 for the Assessment of Lung Motion during Breathing

PURPOSE: To develop a dynamic magnetic resonance imaging (MRI) tagging technique using hyperpolarized helium-3 (HP He-3) to track lung motion. METHODS AND MATERIALS: An accelerated non-Cartesian k-space trajectory was used to gain acquisition speed, at the cost of introducing image artifacts, provid...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Cai, Jing, Sheng, Ke, Benedict, Stanley H., Read, Paul W., Larner, James M., Mugler, John P., de Lange, Eduard E., Cates, Gordon D., Miller, G. Wilson
Natura: Artigo
Lingua:Inglês
Pubblicazione: 2009
Soggetti:
Accesso online:https://ncbi.nlm.nih.gov/pmc/articles/PMC2752969/
https://ncbi.nlm.nih.gov/pubmed/19540059
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.ijrobp.2009.03.051