Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies

Several Monte Carlo systems were benchmarked against published measurements of bremsstrahlung yield from thick targets for 10–30 MV beams. The quantity measured was photon fluence at 1 m per unit energy per incident electron (spectra), and total photon fluence, integrated over energy, per incident e...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Faddegon, Bruce A., Asai, Makoto, Perl, Joseph, Ross, Carl, Sempau, Josep, Tinslay, Jane, Salvat, Francesc
Formato: Artigo
Idioma:Inglês
Publicado em: American Association of Physicists in Medicine 2008
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC2736754/
https://ncbi.nlm.nih.gov/pubmed/18975676
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1118/1.2975150