Comparison of direct and standard antimicrobial disk susceptibility testing for bacteria isolated from blood.

To determine the reliability of early antimicrobial susceptibility testing, we compared the results of direct and standard single-disk diffusion methods for 581 positive blood cultures processed routinely by the clinical microbiology laboratory. The direct procedure differed from the standard one on...