Detection of endotoxin in the plasma of patients with gram-negative bacterial sepsis by the Limulus amoebocyte lysate assay.

A total of 120 Limulus amoebocyte lysate (LAL) determinations were made on plasma obtained from normal, healthy human blood donors. Results demonstrated a mean endotoxin level in blood of 0.02 to 1.57 pg/ml. The amount of Escherichia coli endotoxin added to human plasma samples can be quantitated by...