Bioluminescence screening for bacteriuria.

A rapid screening test (45 min) for bacteriuria was evaluated in 1,000 clinical urine specimens. The test procedure is based upon firefly luciferase analysis of bacterial ATP and uses the Lumac kit and Lumac M2010 Biocounter (3M Co., St. Paul, Minn.). The procedure allows for removal and destruction...