High relaxivity gadolinium modified high density lipoproteins as MRI contrast agents
There is an ongoing desire to produce high relaxivity, Gd-based MRI contrast agents. These may allow for lower doses to be used, which is especially important in view of the current safety concerns surrounding Gd in patients. Here we report the synthesis of a high relaxivity MRI contrast agent, by i...