Nalaganje...

Comparison of the detection of herpes simplex virus in direct clinical specimens with herpes simplex virus-specific DNA probes and monoclonal antibodies.

A comparison of two commercially available kits for rapid herpes simplex virus (HSV) detection directly in patient specimens was performed. The immunofluorescence assay (IFA) utilized monoclonal antibodies to HSV, and the DNA probe assay utilized three HSV sequences cloned into pBR322. A sample of 2...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
izdano v:J Clin Microbiol
Main Authors: Fung, J C, Shanley, J, Tilton, R C
Format: Artigo
Jezik:Inglês
Izdano: American Society for Microbiology (ASM) 1985
Teme:
Online dostop:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC268519/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/2997269/
https://ncbi.nlm.nih.govhttps://doi.org/10.1128/jcm.22.5.748-753.1985
Oznake: Označite
Brez oznak, prvi označite!