Surveillance of susceptibility testing methodologies for Haemophilus influenzae in Canada, including evaluation of disk diffusion test.

We surveyed 75 clinical laboratories to determine if National Committee for Clinical Laboratory Standards (NCCLS) were being used for the susceptibility testing of Haemophilus influenzae. Of the 66 laboratories that performed susceptibility testing, all claimed to follow current NCCLS guidelines. Ho...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Scriver, S R, Hoban, D J, McGeer, A, Moore, T C, Walmsley, S L, Low, D E
Formato: Artigo
Idioma:Inglês
Publicado em: 1994
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC263922/
https://ncbi.nlm.nih.gov/pubmed/7989560