Comparison of the Seradyn Color Vue passive agglutination test and complement fixation for detection of Mycoplasma pneumoniae antibodies.

We compared traditional complement fixation (CF) with a new passive agglutination method, the Seradyn Color Vue (SCV) test (Seradyn, Indianapolis, Ind.), for detection of Mycoplasma pneumoniae antibodies in 170 stored serum samples. The SCV test was 90% sensitive in identifying as positive 27 of 30...