The Use of the Zickel Device for a Malunited Subtrochanteric Femur Fracture

Surgical treatment of adult subtrochanteric femur fractures by internal fixation, using the Jewett nail, has been associated with a high degree of major complications. Jewett nail failures in these fractures can produce functionally disabling varus deformities. The Zickel device is an effective mean...