An evaluation of expanded polytetrafluoroethylene (PTFE) loop grafts in the thigh as vascular access for haemodialysis in patients with access problems.

A total of 21 patients with vascular access problems received 22 PTFE loop grafts in the thigh as vascular access for haemodialysis. Eighteen of 22 grafts supported haemodialysis during the patients' lifetime. Actuarial patient survival was 50% at 2 years with a cumulative graft patency in the...

詳細記述

保存先:
書誌詳細
主要な著者: Slater, N. D., Raftery, A. T.
フォーマット: Artigo
言語:Inglês
出版事項: Royal College of Surgeons of England 1988
主題:
オンライン・アクセス:https://ncbi.nlm.nih.gov/pmc/articles/PMC2498759/
https://ncbi.nlm.nih.gov/pubmed/3415174