Electrode System for the Determination of Microbial Populations

Determinations of microbial populations were carried out by using a new electrode system composed of two electrodes. Each electrode was constructed from a platinum anode and a silver peroxide cathode. The anode of the reference electrode was covered with cellulose dialysis membrane. The response tim...