Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigation

Tension-band wiring is commonly used to treat transverse patella fractures. The most common configuration has parallel Kirschner (K) wires and a stainless steel wire loop placed in a vertically oriented figure of eight. Early mobilisation is important but can cause detrimental displacement at the fr...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
Main Authors: John, J., Wagner, W. W., Kuiper, J. H.
Format: Artigo
Jezik:Inglês
Izdano: Springer-Verlag 2006
Teme:
Online dostop:https://ncbi.nlm.nih.gov/pmc/articles/PMC2266649/
https://ncbi.nlm.nih.gov/pubmed/17033766
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1007/s00264-006-0238-0