Tracer and Nontracer Potassium Fluxes in Squid Giant Axons and the Effects of Changes in External Potassium Concentration and Membrane Potential

The efflux of labeled and unlabeled potassium ions from the squid giant axon has been measured under a variety of experimental conditions. Axons soaked in sea water containing (42)K ions lost radioactivity when placed in inactive sea water according to kinetics which indicate the presence of at leas...