Carregant...
Gating of Na channels in the rat cortical collecting tubule: effects of voltage and membrane stretch
The gating kinetics of apical membrane Na channels in the rat cortical collecting tubule were assessed in cell-attached and inside-out excised patches from split-open tubules using the patch-clamp technique. In patches containing a single channel the open probability (Po) was variable, ranging from...