Control of Nitrous Oxide Exposure in Dental Operatories Using Local Exhaust Ventilation

An experimental portable local exhaust ventilation system was installed in three dental operatories where nitrous oxide was used routinely. Standard methods of exhaust ventilation design used in industry to control exposures to toxic airborne substances were applied to the dental operatory setting....