Use of an Air–Fluid Exchange System to Promote Graft Adhesion During Descemet's Stripping Automated Endothelial Keratoplasty

Dislocation of the graft is a well-recognized complication of Descemet's stripping automated endothelial keratoplasty (DSAEK). We describe a technique to promote adhesion of the graft during DSAEK using an anterior chamber air–fluid infusion and exchange for direct control of the pressure and m...