Measurement of Digoxin in Plasma and its use in Diagnosis of Digoxin Intoxication

A method for measuring the plasma-digoxin concentration uses the measurement of its inhibitory effect on (86)Rb uptake by human red cells in vitro. Patients receiving digoxin in whom there was no clinical evidence of digoxin intoxication had plasma digoxin concentrations ranging from 0·8 to 4·5 mμg....