Mechanical Trauma as a Cause of Late Complications after AneuRx® Stent Graft Repair of Abdominal Aortic Aneurysms

We present a series of 4 patients in whom mechanical trauma was identified as a factor in the development of late complications after AneuR® Stent Graft placement for repair of abdominal aortic aneurysms. In all 4 patients, Type I or III endoleaks (and pseudoaneurysms in 2 patients) were discovered...