लोड हो रहा है...

Analysis of Legionella pneumophila serogroup 6 strains isolated from a hospital warm water supply over a three-year period by using genomic long-range mapping techniques and monoclonal antibodies.

Over a period of 3 years, Legionella pneumophila serogroup 6 strains were isolated from warm water outlets and dental units in the Dental Faculty and from the Surgery and Internal Medicine Clinics at the University of Dresden, Dresden, Germany. In the bacteriological unit of the above-mentioned faci...