Sensitive high-pressure liquid chromatographic assay for amphotericin B which incorporates an internal standard.
We developed a rapid, sensitive, high-pressure liquid chromatographic (HPLC) procedure which incorporates a commercially available internal standard, 1-amino-4-nitronaphthalene, to measure amphotericin B in serum. Recovery was quantitative (greater than or equal to 90%), and the standard curve was l...
Gorde:
| Argitaratua izan da: | Antimicrob Agents Chemother |
|---|---|
| Egile Nagusiak: | , , |
| Formatua: | Artigo |
| Hizkuntza: | Inglês |
| Argitaratua: |
American Society for Microbiology (ASM)
1986
|
| Gaiak: | |
| Sarrera elektronikoa: | https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC180446/ https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/3707107/ https://ncbi.nlm.nih.govhttps://doi.org/10.1128/aac.29.4.584 |
| Etiketak: |
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
|