Carregant...
Failure of thrombolysis by streptokinase: detection with a simple electrocardiographic method
OBJECTIVE—To determine whether simple, readily applicable ECG criteria will allow early prediction of inadequate (< TIMI 3) flow in the infarct related vessel in patients receiving thrombolytic treatment for acute myocardial infarction; and to determine the success of streptokinase in achieving a...
Guardat en:
| Autors principals: | , , , , , , , |
|---|---|
| Format: | Artigo |
| Idioma: | Inglês |
| Publicat: |
2000
|
| Matèries: | |
| Accés en línia: | https://ncbi.nlm.nih.gov/pmc/articles/PMC1760890/ https://ncbi.nlm.nih.gov/pubmed/10908249 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1136/heart.84.2.149 |