Failure of thrombolysis by streptokinase: detection with a simple electrocardiographic method

OBJECTIVE—To determine whether simple, readily applicable ECG criteria will allow early prediction of inadequate (< TIMI 3) flow in the infarct related vessel in patients receiving thrombolytic treatment for acute myocardial infarction; and to determine the success of streptokinase in achieving a...